Development of novel scanning electrochemical microscopic (SECM) methods employing ultra-micro sized ion selective electrodes and using them for discovering fine details of certain corrosion phenomena  Page description

Help  Print 
Back »

 

Details of project

 
Identifier
125244
Type K
Principal investigator Nagy, Géza
Title in Hungarian Új, ultra-mikro méretű ionszelektív elektródokat alkalmazó pásztázó elektrokémiai mikroszkópiás (PEKM) módszerek kidolgozása és alkalmazása egyes korróziós folyamatok sajátságainak felfedezésére
Title in English Development of novel scanning electrochemical microscopic (SECM) methods employing ultra-micro sized ion selective electrodes and using them for discovering fine details of certain corrosion phenomena
Keywords in Hungarian ultra-mikro méretű ionszelektív elektródok, több csövű elektrpásztázó elektrokémiai mikroszkópia (PEKM), korrózió, potenciometriás módszer
Keywords in English ultra-micro sized ion selective electrode, multi-barrel electrode, scanning electrochemical microscopy (SECM), corrosion, potentiometric method
Discipline
Analytical Chemistry (Council of Physical Sciences)60 %
Ortelius classification: Electroanalytics
Material Science and Technology (chemistry) (Council of Physical Sciences)30 %
Physical Chemistry and Theoretical Chemistry (Council of Physical Sciences)10 %
Ortelius classification: Electrochemistry
Panel Chemistry 1
Department or equivalent Department of Chemistry and Physical Chemistry (University of Pécs)
Participants Amangdam Anemana, Timothy
Asserghine, Abdelilah
Filotás, Dániel
Kiss, András
Meiszterics, Zoltán
Nagyné dr. Zengo, Lívia
Starting date 2017-09-01
Closing date 2022-11-30
Funding (in million HUF) 42.455
FTE (full time equivalent) 12.91
state closed project
Summary in Hungarian
A kutatás összefoglalója, célkitűzései szakemberek számára
Itt írja le a kutatás fő célkitűzéseit a témában jártas szakember számára.

A tervezett munka fő célja a pásztázó elektrokémiai mikroszkópiás technika (PEKM) továbbfejlesztése és az új változat alkalmazása gyakorlatilag fontos fémötvözetek korróziós folyamatainak vizsgálatára. A korrózió megelőzésének, gátlásának fontossága közismert. A korróziós folyamatok tanulmányozására, a korróziót gátló eljárások hatékonyságának vizsgálatára számos jól alkalmazható módszer áll rendelkezésre. Ezek az említett módszerek azonban csak a teljes folyamat természetéről, sebességéről, termékeiről adnak általános információt. Nyilvánvaló, hogy a korrózió gátlására irányuló kutatásokban a felület részein végbemenő változásokról nagy felbontású kémiai képet adó analitikai módszerek jól használhatók lehetnek. Ennek megfelelően olyan, viszonylag új elektrokémiai mikro módszerek, mint a pásztázó vibráló elektród technika (PVET, SVET) és a pásztázó elektrokémiai mikroszkópia (PEKM, SECM) a korróziós tanulmányokban is alkalmazásra került. A PEKM a mérőcsúcs mikroszkópiás módszerek egyik változatát képezi. Pásztázó mérőcsúcsként elektrokémiai mikro érzékelőt használ. A PEKM mérések túlnyomó többségében amperometriás üzemmódot használnak. Ugyanakkor potenciometriás méréstechnika, ultramikro ion szelektív elektródok használatával, sokkal kedvezőbb szelektivitást biztosíthat a kémiai mikroszkópiás kép készítéséhez. A tervezett kutatómunkában új potenciometriás mérési módszerek, szelektív pásztázó mérőcsúcsok, mérőcellák kidolgozására és a korróziós vizsgálatok céljára történő használatára kerül sor.

Mi a kutatás alapkérdése?
Ebben a részben írja le röviden, hogy mi a kutatás segítségével megválaszolni kívánt probléma, mi a kutatás kiinduló hipotézise, milyen kérdéseket válaszolnak meg a kísérletek.

A PEKM mérések során a készülék mérőcsúcsa a minta területet pásztázva elektrokémiai jeleket gyűjt különböző helyeken. Határfelületekről készítendő nagyfelbontású kép ultramikro mérőcsúcs és nagyszámú adatgyűjtési pont alkalmazásával érhető el. Az adatgyűjtés ideje hosszabb, ha több mérési pontot választunk. Olyan esetekben, amikor a vizsgált minta állapota változik az időben,- a korróziós folyamatok ilyenek- rövid mérési időre van szükség. A korábbi PEKM mérések nagy részében platina vagy szén mikro elektróddal történő amperometriás detektálást alkalmaztak. Az esetben a válaszidő rövid. Kisebb elektród esetében rövidebb idő alatt jön létre stacionárius jel. Az amperometriás módszer alkalmazható felületi topográfiás kép készítésére is a visszacsatolási hatást kihasználva. Emellett az amperometriás áram jelzi a mérőcsúcs és mintafelület közötti távolságot. A potenciometriás detektáció nem biztosítja ezeket az előnyöket. Kisebb méretű elektród esetében hosszabb idő szükséges a stacionárius cella feszültség jel eléréséhez. A potenciometriás jel nem mutatja a mérőcsúcsnak a felülettől mért távolságát. Nyilvánvaló, hogy fontos fejlesztő lépések szükségesek ahhoz, hogy a potenciometriás PECM egy jól alkalmazható, hatékony, kényelmes módszerré váljon a korróziós vizsgálatokban. A projekt e területen végzett kutatásokat tervez. Várható, hogy potenciometriás és amperometriás PEKM módszerrel készített felületi kémiai képek alkalmasak lesznek egyes korróziós folyamatok finom részleteinek megismerésébe. Iparilag fontos magnézium ötvözetek és a fogászatban újabban intenzíven használt titánötvözetek korróziójának vizsgát tervezzük a kidolgozott módszerek alkalmazásával.

Mi a kutatás jelentősége?
Röviden írja le, milyen új perspektívát nyitnak az alapkutatásban az elért eredmények, milyen társadalmi hasznosíthatóságnak teremtik meg a tudományos alapját. Mutassa be, hogy a megpályázott kutatási területen lévő hazai és a nemzetközi versenytársaihoz képest melyek az egyediségei és erősségei a pályázatának!

A pásztázó elektrokémiai mikroszkópia (PEKM) egy hatékony módszer, amely segítségével mikrokörnyezetben lezajló folyamatokról nagy térbeli felbontású kémiai információ nyerhető. A módszer elméletéről, alkalmazásairól kiterjedt irodalom szól. A módszerrel végzett mérések túlnyomó többségében amperometriás méréstechnikát alkalmaznak nemesfém vagy szén mikroelektródok használata mellett. Ionszelektív elektródokkal az amperometriás méréseknél szelektívebb kémiai jel nyerhető. A potenciometriás detektálásnak a PEKM mérésekhez való adaptálása azonban nem bizonyult egyszerűnek. Ezért A.J. Bard, a PEKM inventora együttműködést kezdeményezett Pungor Ernő nemzetözileg jól ismert, az ionszelektív elektródok fejlesztése területén dolgozó kutatócsoportjával. Mint a magyar csoport tagja a PEKM mikroszkópiás kutatásokat 1992-ben, röviddel a módszer kifejlesztése után kezdtem el. Azóta munkatársaimmal a módszer fejlesztésére irányuló kutatásokat végzünk, illetőleg alkalmazzuk a módszert kutató munkánkban. Eredményeinkről könyv fejezeteket, közleményeket írtunk. Ezek ismertté tették munkánkat, különösen a potenciometriás mikro elektródokkal elért eredményeinket. A PEKM-ás méréstechnika fő alkalmazási területét a fiziológiás folyamatok tanulmányozása jelenti. Napjainkig ezeknél sokkal kisebb érdeklődés mutatkozott a korróziós folyamatok tanulmányozása terén jelentkező előnyök irányában. Pályázati munkában a potenciometriás PEKM módszert továbbfejlesztjük. Csökkentjük a módszer alkalmazásához szükséges mérési időt, speciális ionszelektív ultramikro elektródos mérőcsúcsokat fejlesztünk ki, új pásztázási programokat írunk és alkalmazunk. A módszer fejlesztésének fő irányát annak a korróziós folyamatok mikro skálán történő tanulmányozásához történő illesztése képezi. Ionszelektív mikro elektródok képesek detektálni a korrodáló felület aktív pontjaiból kilépő fémionokat. Potenciometriás PEKM módszerrel mikroszkópiás térkép készíthető a felületen lévő különböző korrózió aktivitású pontokról. Korróziót gátló kezelések hatása jól tanulmányozható. Reményeink szerint a tervezett munka fontos információt szolgáltat majd néhány gyakorlatilag fontos korróziós folymat gátlására szolgáló kezelések kidolgozásához

A kutatás összefoglalója, célkitűzései laikusok számára
Ebben a fejezetben írja le a kutatás fő célkitűzéseit alapműveltséggel rendelkező laikusok számára. Ez az összefoglaló a döntéshozók, a média, illetve az érdeklődők tájékoztatása szempontjából különösen fontos az NKFI Hivatal számára.

Amint az jól ismert a különböző közegekkel érintkező fémtárgyak korróziója óriási gazdasági veszteségeket okoz. A korróziós folyamatok finom lépéseinek megismerése nagy fontosságú lehet ahhoz, hogy hatékony korróziót gátló módszerek kidolgozására kerüljön sor. A projekt keretében egy viszonylag új módszer, a pásztázó elektrokémiai minroszkópia (PEKM) továbbfejlesztésén dolgozunk. Célunk, hogy azt különösen alkalmassá tegyük korróziós vizsgálatok hatékony végzésére. Alapulva az ionszlektív elektródok fejlesztése területén, a Pungor Ernő által alapított és hosszú ideig vezetett, híres, magyar kutatócsoport felfedezésein ultramikro méretű elektródokat fejlesztünk ki és alkalmazunk a korróziós PEKM mérésekben. A módszert eredetileg fiziológiai folyamatok mikro skálán történő vizsgálatára használták. A szelektív mikro szenzorok képesek jelezni ionok koncentrációját korrodálódó fémfelületek mikrokörnyezetében. Így a felület aktív és passzív pontjairól térképszerű kép készíthető. Ez segítséget nyújt a fémoldódást eredményező folyamat részlépéseiről és segíthet a káros folyamat gátlását eredményező módszer kidolgozásában. A magnézium öntvények híresek jó mechanikai sajátságaikról. Alkalmazást nyernek a járműiparban. Korrózióval szembeni ellenállásuk azonban kicsiny. A kísérletekben magnéziumötvözetek korróziós sajátságait tervezzük vizsgálni a továbbfejlesztett PEKM módszerrel. A titánötvözetek korróziónak ellenálló sajátságainak köszönhetően széles területen alkalmazásra kerülnek fogászati implantátumokban és a gyógyászat más területein. Vizsgálni fogjuk, hogy gyulladásos szövetekben előforduló egyes anyagok mennyiben hatnak a titánötvözetek korrózióval szembeni viselkedésére.
Summary
Summary of the research and its aims for experts
Describe the major aims of the research for experts.

1. The main goals of the proposed research work are the further development of the scanning electrochemical microscopy technique (SECM) and use its advanced version for investigation corrosion processes of certain practically important alloys. Importance of hindering or avoiding corrosion of metal structures is common sense today. Straightforward, well established methods are used in studying the corrosion processes as well as the effect of different corrosion hindering treatments, coatings, composition changes. Those methods however, are capable just reporting on the overall nature, speed, and products of different corrosion processes. It is generally expected that analytical methods providing high resolution chemical images about interfaces or surfaces can help fighting corrosion. Accordingly from the relatively new electrochemical methods the SVET (scanning vibrating electrode technique) and the SECM are getting popular in laboratories dealing with corrosion studies. SECM is a version of the probe microscopy. It uses electrochemical micro-sensors as scanning tip. Overwhelming majority of the SECM measurements has been done with amperometric detection. On the other hand using potentiometric detection with ultramicro ion selective electrodes can give better selectivity in forming the chemical micro image. In the proposed research new potentiometric measuring methods, selective sensing tips, measuring cells specially applicable for corrosion studies will be developed. The applicability of those will be tested studying nature of corrosion reactions and in investigation of action of different corrosion fighting treatments.

What is the major research question?
Describe here briefly the problem to be solved by the research, the starting hypothesis, and the questions addressed by the experiments.

In practice of SECM the measuring tip travels along the sample area and collects electrochemical signal at different locations. Ultra micro sized tip and high number of data collecting spots are needed for obtaining high resolution chemical image about interfaces. The time period needed for the data collection will be longer if more data collection spot is set. In cases when state of the studied sample changes in time, like in corrosion processes, then short measuring time is needed. In early SECM experiments amperometric detection with platinum or carbon microelectrodes were used. The response time of an amperometric microelectrode is short. The smaller the area the shorter time is needed for achieving steady signal. Furthermore the amperometric sensors interacts with the studied surface. Owing to the feedback effect it can provide topographic image and also can show the measuring tip – sample surface distance. The potentiometric measuring method does not have these advantages. The smaller is the electrode the more time is needed for achieving steady cell voltage signal, and the signal does not show the distance between the tip and the surface. In order to make potentiometric SECM a convenient, popular, powerful and advantageous method in corrosion studies important steps forward are needed. The proposed work is aiming to make important steps in this field. It is expected that images made by amperometric and potentiometric SECM can help explaining the fine details of certain corrosion processes. Industrially important magnesium alloys, and titanium alloys used in dental treatments will be investigated.

What is the significance of the research?
Describe the new perspectives opened by the results achieved, including the scientific basics of potential societal applications. Please describe the unique strengths of your proposal in comparison to your domestic and international competitors in the given field.

The scanning electrochemical microscopy (SECM) is a very powerful method that can be effectively used for obtaining chemical information with high spatial resolution about processes taking place at micro environment. Extensive literature, review papers, books and book chapter appeared about theory and applications of the method. Amperometric detection, with noble metal or carbon microelectrodes has been used in most of the SECM measurements. As it is well known ion selective sensors with potentiometric detection can provide more chemical selectivity than amperometry. However, for adapting potentiometric detection with ion selective microelectrode to SECM was not found an easy straightforward task. This is why A. J. Bard, the inventor of the SECM started cooperation with E. Pungor’s internationally well-known research group of the field of ion selective electrodes. As a member of the Hungarian group I started my SECM research in1992 just a few years after the invention of the technique (1989). Ever Since we have been doing research in developing the field and in application of it. Book chapters, review and research papers appeared as our contribution to the development of the SECM method. It made highlights of our group, specially the results achieved with potentiometric microsensors known.
One of the main application fields of SECM appears to be the investigation of physiological processes. Up till now much less attentions have been given on advantages of using it in corrosion studies. In the proposed work the potentiometric SECM method will be further developed. Attempts will be made to shorten the scanning time, to work out special measuring tips and scanning programs. In these special care will be taken for enhancing applicability of the method for investigation of corrosion processes in the micro scale. Ion selective microelectrodes can detect metal ions released by active spots of corroding surfaces. With potentiometric SECM the distribution of surface spots of different activity can be mapped. Effect of corrosion fighting treatments on the process advantageously can be studied. Hopefully our planned work will give important results to be used in fighting certain corrosion processes.

Summary and aims of the research for the public
Describe here the major aims of the research for an audience with average background information. This summary is especially important for NRDI Office in order to inform decision-makers, media, and others.

As it is well known, corrosion processes of metal items being in contact with different environment cause tremendous loss for the society. The discovery of fine details of corrosion is vital to be able to fight effectively the deteriorating process. In the proposed project a relatively new method, the scanning electrochemical microscopy (SECM) applicable for investigation of processes in microenvironments will be improved. Based on the discoveries achieved in field of ionselective electrodes by the famous Hungarian research group funded, and longtime led by Ernő Pungor, ultramicro sized electrodes will be employed. The method originally was used in micro scale studies of biologic processes. It will be modified for corrosion studies. Selective sensors capable detecting ion concentration in the micro vicinity of corroding metal surfaces will be modified and used. The map of the surfaces showing corrosion active and passive grains will be made, to help understanding details of the metal dissolution and to fighting against the deterioration. Magnesium alloys that are known for their good mechanic properties concerning application in transportation industries, but poor corrosion resistance will be employed as sample material in the planned experiments. The benefit of different corrosion fighting treatments will be investigated detecting the evolved magnesium ion concentration with improved SECM. Titanium alloys with good corrosion properties are extensively used in dental implants and in other product of biomedical engineering. The corrosion resistance in artificial inflamed tissue environment will also be studied.





 

Final report

 
Results in Hungarian
A terveknek megfelelően, a pályázati munka eredményei egyrészt a pásztázó elektrokémiai mikroszkópiás módszer (PEKM) fejlesztésére irányuló kutatások-, másrészt a PEKM módszert alkalmazó kísérletek során keletkeztek. A metodikai fejlesztés területén a mások által ritkábban használt potenciometriás változathoz jól alkalmazható szelektív mérőcsúcsokat, azok több funkciós változatait fejlesztettünk ki. Különböző lehetőségek alkalmazásával sikerült a pasztázási időt rövidíteni. Új pozicionáló rendszer-, mérőállomás-, mérőcella rendszer - alkalmazásával, valamint mérő/értékelő program kifejlesztésével sikerült házi készítésű PEKM készülékünket jelentősen továbbfejleszteni. Tanulmányoztuk határfelületen lejátszódó egyes folyamatok által létrehozott elektrosztatikus tér zavaró hatásának mértékét és annak kiküszöbölésének lehetőségeit. PEKM méréstechnika alkalmazásával különböző határfelületi folyamatok részlépéseiről sikerült közeli információt szerezni. Cink és plasztik réteggel bevont acél- lemez elvágott felületén létrejövő korróziós folyamatokat tanulmányoztunk antimon és cink mikro elektródos PEKM módszerrel. 3D nyomtatással készült fémtárgyak korróziós sajátságairól szereztünk információt. Megállapítottuk, hogy a titán ötvözetből készített gyógyászati implantátumok felületén a sérült korrózióvédő réteg regenerációja viszonylag hosszú időt vehet igénybe. Tanulmányoztuk, hogy elektrokémiai polarizáció hogy hat titán ötvözet korrózióvédő rétegének aktivitására.
Results in English
According to the original plans, the results of the project were obtained partly in the work aiming to further develop the scanning electrochemical microscopy (SECM), partly in experiments employing the SECM. In further developing of SECM selective measuring tips, their multifunction variety, well applicable ones for the less frequently used potentiometric version has been developed. Testing different ways the necessary scanning time could be shortened. Our home made SECM apparatus could be further developed employing new positioning unit-, advanced measuring work station-, novel measuring cell holder and writing new robust measuring / evaluating programs. Detailed investigation of the interfering action of electrostatic field resulted by on-going certain reaction has been carried out. Measuring technique for avoiding I has been proposed and tested. Information about fine steps of different heterogeneous reaction could be gathered using the SECM method. Intensity and nature of corrosion processes at cut edge surface of mild steel foil coated with Zn and plastic layers have been studied by SECM method using ion selective Zn2+ and antimony micro tips. Information was gathered about different 3D printed metal alloys. Studying the self- healing processes of damaged corrosion protecting oxide film on titanium alloys, it was found that about 30 min. is needed for complete healing in ambient conditions. Effect of electric polarization on corrosion resistance of dental implant alloys has been investigated.
Full text https://www.otka-palyazat.hu/download.php?type=zarobeszamolo&projektid=125244
Decision
Yes





 

List of publications

 
A. Asserghin, M. M-Kosanović , L. Nagy, G.Nagy,: In situ monitoring of the transpassivation and repassivation of the passive film on nitinol biomaterial by scanning electrochemical microscopy, Electrochemistry Communications ? (2019) 1–4, 2019
A. Asserghine, A. M. Ashrafi, A. Mukherjee, F. Petrlak, Z. Heger, P. Svec, L. Richtera, L. Nagy, R. M. Souto, G. Nagy, V. Adam: , In Situ Investigation of the Cytotoxic and Interfacial Characteristics of Titanium When Galvanically Coupled with Magnesium Using Scanning Electrochemical Microscopy, ACS Appl. Mater. Interfaces 13 (2021), 43587−43596, 2021
D. Filotas, L. Nagy, G. Nagy, R.M. Souto: New insights on the influenceof aluminum on the anomalous hydrogen evolution of anodized magnesium using scanning electro-chemical Microscopy, Electrochimica Acta 391(2021), 138915, 2021
D. Filotás, B.M. Fernández-Pérez, L. Nagy, G. Nagy, R.M. Souto,: Investigation of anomalous hydrogen evolution from anodized magnesium using a polarization routine for scanning electrochemical microscopy, J. of Electroanal. Chem. 895, (2021), 115538, 2021
J. S Ben, A. El Guerraf, A. Kiss, A. El Azrak , E.A. Bazzaoui, R.Wang, J.I. Martins, M Bazzaoui,: Analyses of scanning electrochemical microscopy and electrochemical impedance spectroscopy in direct methanol fuel cells: permeability resistance and proton conductivit, J. Solid State Electrochem, 24 (2020) 1551-1565, 2020
L. K. Muthuri, L. Nagy, G. Nagy,: Chronopotentiometric method for assessing antioxidant activity: A reagentless measuring technique, Electrochem. Commun. 122 (2021) 106907, 2021
D.Filotás, J. Izquierdo, B. M. Fernández-Pérez, L. Nagy, G. Nagy, R. M. Souto: Contributions of Microelectrochemical Scanning Techniques for the Efficient Detection of Localized Corrosion Processes at the Cut Edges of Polymer-Coated Galvanized Steel, Molecules, 27 (2022), 2167.(17pages) https://doi.org/10.3390/molecules27072167, 2022
L. K. Muthuri, L. Nagy, G. Nagy,: Evaluating the antioxidant activity of different species using a novelreagentless chronopotentiometric method,, Electrochemistry Communications, 139 (2022) 107311, https://doi.org/10.1016/j.elecom.2022.107311, 2022
A. Asserghine, ✉ , D. Filotás, L. Nagy, R. M. Souto ,G. Nagy npj Material s Degradation (2022)6:57 IF: 6.042021, ; https://doi.org/10.1038/s41529-022-00270-0: Do titanium biomaterials get immediately and entirely repassivated? A perspective, npj Material s Degradation (2022)I6:57 ; https://doi.org/10.1038/s41529-022-00270-0, 2022
D. Filotás, A. Asserghine, T. Nagy, L. Asztalos, F. Kovács, J. Dobránszky, L. Nagy, G. Nagy: Nickel coated graphite microparticle based electrodes for carbon dioxide reduction in monoethanolamine medium,, Electroanalysis, 33 (2021) 208-215, 10.1002/elan.202060037, 2021
Z. Meiszterics, A, Kiss, D. Filotás, A. Abdelilah, L. Nagy, G. Nagy: Pásztázó Elektrokémiai Mikroszkópiás (PEKM) módszer fejlesztése és alkalmazása korróziós folyamatok tanulmányozására, Development of scanning electrochemical microscopy, Magy. Kém. Foly. 128 (2022/) 79-85, DOI: 10.24100/MKF.2022.02.79, 2022
A.Asserghine, M. Medvidović-Kosanović, A. Stanković, L. Nagy, R. M. Souto, G. Nagy,: A scanning electrochemical microscopy characterization of the localized corrosion reactions occurring on nitinol in saline solution after anodic polarization, Sensors and Actuators B: Chemical, accaepted,, 2020
A.Asserghine, M.Medvidović-Kosanović, L.Nagy, R. M.Souto, G.Nagy,: A study of the electrochemical reactivity of titanium under cathodic polarization by means of combined feedback and redox competition modes of scanning electrochemical mi, Sensors and Actuators B: Chemical, 320(2020) 128339, https://doi.org/10.1016/j.snb.2020.128339, 2020
D. Filotas, B.M. Fernandez-Perez, L. Nagy, G. Nagy, R.M. Souto,: A novel Scanning Electrochemical Microscopy strategy for the investigation of anomalous hydrogen evolution from AZ63 magnesium alloy, Sensors and Actuators: B. Chemical (Accepted paper), DOI: https://doi.org/10.1016/j.snb.2020.127691, 2020
Z. Meiszterics, A. Asserghine, A. Kiss, L. Nagy, T. Zsebe, G. Nagy,: Scanning Electrochemical Potentiometric Scanning Electrochemical Microscopy (SECM) investigation of 3D printed parts produced by CMT welding technology, Electroanalysis 2020 (accepted paper) DOI: 10.1002/elan.201900678, 2020
A. Stanković, Ž. Kajinić, J.V. Turkalj, Ž. Romić, M. D. Sikirić, A. Asserghine, G. Nagy, M. Medvidović-Kosanović: Voltammetric determination of arsenic with modified glassy carbon electrode, Electroanalysis (2020)10.1002/elan.201900666, 2020
D. Filotás, B.M. Fernández-Pérez, L. Nagy, G. Nagy, R.M. Souto, Multi-barrel electrodes containing an internal micro-reference for the improved visualization of galvanic corrosion processes in magnesium-based materials using potentiometric scanning electrochemical microscopy,: Multi-barrel electrodes containing an internal micro-reference for the improved visualization of galvanic corrosion processes in magnesium-based materials using potentiom, SENSORS AND ACTUATORS B-CHEMICAL (0925-4005 ): 296 p. 126625. Paper 126625. (2019, 2019
. A. Asserghine , M. M-Kosanović , L. Nagy, G.Nagy, Electrochemistry Communications ? (2019) 1–4, IF 4.3962017: In situ monitoring of the transpassivation and repassivation of the passive film on nitinol biomaterial by scanning electrochemical microscopy, Electrochemistry Communications, 107, October 2019, 106539, 2019
S. J. Keszei, Sz. Balogh, Cs. Fehér, L. Nagy, N. Tumanov, J. Wouters, Gy. Lendvay, R. Skoda-Földes: Molecular recognition of strong acids by a 2‐ureido‐4‐ferrocenyl pyrimimidine receptor, Eur. J. of Inorg. Chem. https://doi.org/10.1002/ejic.201900803,, 2019
D. Filotás, A. Asserghine, T. Nagy, L. Asztalos, F. Kovács, J. Dobránszky, L. Nagy, G. Nagy: Nickel coatedgraphite microparticle based electrodes for carbon dioxide reduction in monoethanolamine medium, Electroanalysis, 10.1002/elan.202060037 (Accepted paper), 2020
D. Filotés, T. Nagy, L. Nagy,* P. Mizsey, G. Nagy: Extended Investigation of Electrochemical CO2Reduction in Ethanolamine Solutions by SECM, Electroanalysis 30 (2018) 690 – 697, 2018
Asserghine A, Filotás D, Nagy L, Nagy G: Scanning electrochemical microscopy investigation of the rate of formation of a passivating TiO2 layer on a Ti G4 dental implant, ELECTROCHEM COMMUN 83: 33-35, 2017
Dániel Filotás, B M Fernández-Pérez, J Izquierdo, András Kiss, Lívia Nagy, Géza Nagy, R M Souto: Improved potentiometric SECM imaging of galvanic corrosion reactions, CORROS SCI 129: 136-145, 2017
D. Filotás,B. M. Fernandez-Perez,A. Kiss, L. Nagy, G. Nagy, R. M. Souto: Double Barrel Microelectrode Assembly to Prevent Electrical Field Effects in Potentiometric SECM Imaging of Galvanic Corrosion Processes, Journal of The Electrochemical Society, 165(5) C270-C277 (2018), 2018
A. Asserghine, D. Filotás , B. Németh, L. Nagy, Géza Nagy: Potentiometric scanning electrochemical microscopy for monitoring the pH distribution during the self-healing of passive titanium dioxide layer on titanium dental root im, Electrochemistry Communications 95 (2018) 1–4, 2018





 

Events of the project

 
2017-10-26 12:17:19
Résztvevők változása




Back »