Microchip-based double 1D capillary eletrophoresis  Page description

Help  Print 
Back »

 

Details of project

 
Identifier
42897
Type K
Principal investigator Kilár, Ferenc
Title in Hungarian Kétszer 1D kapilláris elektroforézis chip technológia
Title in English Microchip-based double 1D capillary eletrophoresis
Panel Chemistry 1
Department or equivalent Institute of Bioanalytics (University of Pécs)
Participants Belágyi, József
Guttman, András
Kocsis, Béla
Konecsni, Tünde
Kustos, Ildikó
Starting date 2003-01-01
Closing date 2005-12-31
Funding (in million HUF) 4.140
FTE (full time equivalent) 0.00
state closed project





 

Final report

 
Results in Hungarian
A projekt ütemezése során izoelektromos fókuszálás és zónaelektroforézis kisérleteket folytattunk különböző analitikai célokkal. Ebben szerepelt bakteriális fehérjék vizsgálata, optikai izomerek elválasztása, speciális detektálási technikák (pl. fluoreszcens) alkalmazásának megvizsgálása. A már rendelkezésre álló PrinCE moduláris „1D” kapilláris elektroforézis készüléken a kapilláris izoelektromos fókuszálás mobilizálási lépésének pulzáló módú elvégzésére a készülék alkalmas. Uncoated (kezeletlen) és coated (fedett) kapillárisok alkalmazásának összehasonlítása történt. Standard fehérjekeverékek és bakteriális sejtlizátumok analízise izoelektromos fókuszálással, tipikus izoelektroferogramok gyűjtése történt. A második dimenzió, vagyis elsősorban a zóna-elektroforetikus elválasztások esetében is több lépést végeztünk. Az injektált zónákat alkotó pufferhatású amfolit-komponensek és a második dimenzióban használt SDS együttes jelenléte elektroforézisre gyakorolt hatását vizsgáltuk. A témában közreműködő hazai és külföldi kutatók az elmúlt két évtizedben a projektben felvázolt kutatási területeken dolgoztak és dolgoznak. Szakmai eredményeik felölelik a kapilláris elektroforézis metodikai-technikai fejlesztésében és különböző alkalmazásokban való munkáik eredményeit.
Results in English
The project prvided a possibility to make isoelectric focusing and zone-electrophoretic runs for a possible coupling this two techniques. First of all bacterial proteins, optical isomers were analysed, and the possibility of using fluorescens techniques were studied. The modular PRINCE electrophoresis equipment should the possibility to use a pulsed mode modification of isoelectric focusing. We compared the usability of coated and uncoated capillaries in IEF. Both, standard protein mixtures and also bacterial proteins were investigated. The second dimension, i.e. zone electrophoresis has been used. We tried the application of this method for the analysis of the ampholytes, which would be the most important question when the two technique is coupled sequentially. The researchers in this topic has been participating for long time in the developmenet and application of IEF and CE techniques. Their results provided a very good basis for the further developing steps.
Full text http://real.mtak.hu/833/
Decision
Yes





 

List of publications

 
Konecsni, T. and Kilár, F.: Monitoring of the conjugation reaction between human serum transferrin and fluorescein isothiocyanate by capillary electrophoresis, Journal of Chromatography A 1051 (2004) 135-139., 2004
Poór, V., Biró, I., Bufa, A., Gáti, Á., Fenyvesi, I., Juricskay, S., Tényi, T., Kilár, F.: Urinary steroids in young women with eating disorders, J. Biochem. Bioph. Meth. 61 (2004) 199-205., 2004
Kilár, F.: Capillary isoelectric focusing, in: Electrokinetic phenomena (eds. A. Rathore, A. Guttman), Marcel Dekker, New York, 2004
Végvári, Á. and Kilár, F.: Evolution and development of isoelectric focusing, in: Handbook of isoelectric focusing and proteomics (D. Garfin and S. Ahuja, eds.) Elsevier Inc., 2005
Gagyi, L., Gyéresi, Á. and Kilár, F.: Role of chemical structure in stereoselective recognition of beta-blockers and H1-antihistamines by human serum transferrin in capillary zone electrophoresis, J. Mol. Recognition, 2006
Kilár, F., Rezeli, M., Páger, Cs., Kuti, P., Gagyi, L. and Gyéresi, Á.: Novel approaches for studying drug-protein interaction with CE, CE-MS and model calculations, MSB'2006, Amsterdam, The Netherlands, 2006
Busnel, J-M., Kilár, F., Ka¹ièka, V., Descroix, S., Hennion, M-C. and Peltre, G.: Carrier ampholytes-based capillary electrophoresis as an alternative to capillary zone electrophoresis in classical background electrolytes, Journal of Chromatography A 1087 (2005) 183-188., 2005




Back »